Characteristics
- When used correctly, Cinta Sept works reliably against enveloped viruses, bacteria and yeasts
- Proven limited virucidal activity = destroys enveloped viruses of any kind, including the coronavirus SARS CoV-2 as well as possible mutants of this virus
- Usable in all leading solvents: SOLVONK4, perchlorethylene, hydrocarbons, intense® and SENSENE™
- Use only in distilling dry cleaning machines
- Gentle to colors and fibers
- Dermatest certified with „excellent”
Listings & norms
Proof of effectiveness:
Virucidal according to EN 14476:2019 (Vaccinia Ankara) (limited virucidal activity = effective against enveloped viruses such as SARS-CoV-2)
- 4 ml/l | 20 °C/68 °F | 5 min reaction time
Bactericidal according to EN 1276 and EN 13727 (Staphylococcus aureus, Enterococcus hirae, Escherichia coli, Pseudomonas aeruginosa)
- 4 ml/l | 20 °C/68 °F | 5 min reaction time
Levurocidal according to EN 1650 and EN 13624 (Candida albicans)
- 4 ml/l | 20 °C/68 °F | 5 min reaction time
Notified as a biocide in the UK. Use biocides safely. Always read the label and product information before use.
Chemical-physical data
Appearance | Clear, light yellow liquid |
---|---|
Density | 0.97 g/ml (20 °C/68 °F) |
Viscosity | 25–35 mPa·s (20 °C/68 °F) |
pH value | 11.5 (20 °C/68 °F) |
Flash point | 75 °C/167 °F (PMCC) |
Solubility | Solvable/mixable in SOLVONK4, perchloroethylene, hydrocarbons, intense, SENSENE, and water |
Application
Application of Cinta Sept in 2-bath disinfecting cleaning procedure
1st bath:
- Fill up from working tank to low level, 1:3
- Dosage of 4 ml Cinta Sept per liter of solvent in the 1st bath
- 5 min cleaning time in the pump circuit
- Drain the bath to distillation, extract 1 min to distillation
2nd bath:
- Fill up from the working tank (drain work tank) and topping up solvent from the clean tank to high level, 1:5
- 3 – 5 min filter cycle
- Dosing of the dry cleaning detergent after the filter circuit with 0.75% of machine capacity
- Continue cleaning in the same liquor for 3 more minutes in pump circuit
- Drain to the working tank 90 s, extract to the working tank 3 – 5 min
- Drying
Cinta Sept can be added via automatic pump (recommended) or manually via the button trap.
Storage & dispatch
In closed canisters Cinta Sept has a minimum shelf life of 3 years from date of production.
The product is not sensitive to frost, but becomes more viscous at low temperatures. For correct dosing with dosing devices, it should be tempered to + 15 ° C/59 °F before use.
Close canister after use.